GP26Manufacturer-listed size; suffix and drive remain to be specified.
Enquire with this reference →
DESMI ROTAN · Product family
ROTAN GP is a compact cast-iron option for clean, non-abrasive liquid transfer. Its general-purpose construction is a starting point for oil and compatible utility-fluid duties with moderate viscosity.
EXPLORE THIS PRODUCT DOSSIER
ENGINEERING DATA
Independent family limits. They are not simultaneous operating points and do not establish the rating of an individual pump size.
| Parameter | Published reference |
|---|---|
| Maximum family flow | 50 m³/h |
| Maximum differential pressure | 16 bar |
| Maximum speed | 1,750 rpm |
| Maximum viscosity | 7,500 cSt |
| Maximum liquid temperature | 150 °C |
IDENTIFY THE RIGHT BUILD
A family or hydraulic size is the starting reference. Include the complete nameplate designation, serial number, materials, seals, drive and connection details when ordering.
GP26Manufacturer-listed size; suffix and drive remain to be specified.
Enquire with this reference →GP33Manufacturer-listed size; suffix and drive remain to be specified.
Enquire with this reference →GP41Manufacturer-listed size; suffix and drive remain to be specified.
Enquire with this reference →GP51Manufacturer-listed size; suffix and drive remain to be specified.
Enquire with this reference →GP66Manufacturer-listed size; suffix and drive remain to be specified.
Enquire with this reference →Cast-iron pump; seal and bearing options require fluid review.
Check abrasiveness and chemical compatibility first. Choose the connection size and speed from the duty curve, and include the required motor standard.
DFIN reviews the operating point together with the suction condition and drive. Supply the fluid properties at both start-up and normal operation so the proposed arrangement can be checked against the appropriate curve.
DFIN application links identify duties to discuss, subject to the specified fluid and complete pump configuration.
Use the pump serial number, complete designation and assembly drawing to identify the shaft seal or packing, rotor, idler, bushes, gaskets and relief-valve components.
Send the required component positions and the existing material codes with your enquiry. Kit numbers are confirmed against the pump build; a WILDEN Air Kit or Wet Kit does not apply to this gear-pump design.
Use the selected model’s operating manual for isolation, draining, inspection and reassembly. Report leakage, unusual noise, loss of output or visible wear with photographs and the operating history. DFIN can use the equipment identity and drawing positions to prepare a parts enquiry.
Request matching service parts →DFIN KNOWLEDGE BASE
Shanghai Dfin Pump Co., Ltd. has reorganised the available product facts into practical notes for identification, selection, application review and maintenance planning. These notes support an initial comparison; the final duty point and order code still require project-specific confirmation.
PERFORMANCE NOTE
Maximum family flow: 50 m³/h; Maximum differential pressure: 16 bar; Maximum speed: 1,750 rpm; Maximum viscosity: 7,500 cSt. These figures describe the documented family or model reference; the usable duty point must be checked against speed, liquid properties, suction conditions and the selected drive.
MODEL IDENTIFICATION
Identification references include GP26, GP33, GP41, GP51, GP66. Use the complete nameplate designation, serial number, connection, materials, seal arrangement and drive details when requesting a replacement or quotation.
APPLICATION REVIEW
Cast-iron pump; seal and bearing options require fluid review. Typical duties to review include Lubricating and compatible waste oils, Glycol and other compatible clean liquids. Check abrasiveness and chemical compatibility first. Choose the connection size and speed from the duty curve, and include the required motor standard.
SERVICE PLANNING
Use the pump serial number, complete designation and assembly drawing to identify the shaft seal or packing, rotor, idler, bushes, gaskets and relief-valve components. Isolate the equipment, follow the applicable maintenance procedure and confirm every replacement item against the installed configuration before ordering.
PRODUCT & ENGINEERING FAQ
Use these answers to prepare a technically complete comparison and enquiry.
Start with the real duty point: fluid, flow, differential pressure or head, temperature, viscosity, solids, suction condition and operating pattern. DFIN then reviews size, materials, sealing and drive.
No. They describe independent catalog boundaries for the family or model. The selected point must be checked against the applicable curve, size, speed, fluid and drive arrangement.
Provide the full nameplate designation and serial number plus materials, seal arrangement, ports, drive, motor supply and any special option. A family name alone is not an order code.
Yes. Send the equipment identity, drawing position, existing part code, photographs, material and failure description. DFIN can prepare a parts enquiry matched to the installed configuration.
Include quantity, fluid data, operating point, installation, connection standard, available utilities, hazardous-area requirements and delivery destination. For a replacement, include the nameplate and current drawing.
SHANGHAI DFIN PUMP CO., LTD.
Send the full model and serial number, quantity, fluid, required flow and pressure, temperature, viscosity, installation details and delivery destination. For a replacement, attach the nameplate and existing drawing.
Prepare an enquiry for ROTAN GPOnline support

Hi! How can we help?
We normally reply during China business hours.