Skip to content
dfin88@dfinsewagepump.com+86 21 31263176Industrial pump solutions since 2012
DESMI ROTAN CD — DFIN catalog reference
DFIN catalog image. Final materials, drive and supplied configuration follow the confirmed quotation.

DESMI ROTAN · Product family

DESMI ROTAN Stainless-steel chemical-duty internal gear pump CD for Compatible acids and alkalis

ROTAN CD combines the internal-gear pumping principle with stainless-steel construction for chemically demanding liquids. DFIN reviews the complete wetted path, including seals and bearings, for the specified composition.

Maximum family flow250 m³/h
Maximum differential pressure16 bar
Maximum speed1,750 rpm
DFIN technical record reviewed 2026-09-15. Availability and complete order code are confirmed with your enquiry.

EXPLORE THIS PRODUCT DOSSIER

Product, engineering and service information in one place

ENGINEERING DATA

Technical specifications

Independent family limits. They are not simultaneous operating points and do not establish the rating of an individual pump size.

ParameterPublished reference
Maximum family flow250 m³/h
Maximum differential pressure16 bar
Maximum speed1,750 rpm
Maximum viscosity250,000 cSt
Maximum liquid temperature250 °C

IDENTIFY THE RIGHT BUILD

Models & configuration

A family or hydraulic size is the starting reference. Include the complete nameplate designation, serial number, materials, seals, drive and connection details when ordering.

Choose the size from the required duty point, then confirm the complete construction code with DFIN. No unverified suffix combinations are listed as orderable products.

Materials & performance

Stainless-steel construction; application-specific bushes and seals.

Provide concentration, operating temperature and cleaning chemicals. Confirm seal arrangement and material compatibility before evaluating the proposed speed.

DFIN reviews the operating point together with the suction condition and drive. Supply the fluid properties at both start-up and normal operation so the proposed arrangement can be checked against the appropriate curve.

Application industries

DFIN application links identify duties to discuss, subject to the specified fluid and complete pump configuration.

Typical duties to review

  • Compatible acids and alkalis
  • Resins, soaps and shampoo
  • Temperature-controlled process liquids

ROTAN documentation does not establish FDA / 3-A approval for these pumps. A food-related duty needs a separate review of hygiene, cleaning and the required documentation.

Compatible parts & service

Use the pump serial number, complete designation and assembly drawing to identify the shaft seal or packing, rotor, idler, bushes, gaskets and relief-valve components.

Send the required component positions and the existing material codes with your enquiry. Kit numbers are confirmed against the pump build; a WILDEN Air Kit or Wet Kit does not apply to this gear-pump design.

Maintenance planning

Use the selected model’s operating manual for isolation, draining, inspection and reassembly. Report leakage, unusual noise, loss of output or visible wear with photographs and the operating history. DFIN can use the equipment identity and drawing positions to prepare a parts enquiry.

Request matching service parts →

DFIN KNOWLEDGE BASE

DFIN technical notes for ROTAN CD

Shanghai Dfin Pump Co., Ltd. has reorganised the available product facts into practical notes for identification, selection, application review and maintenance planning. These notes support an initial comparison; the final duty point and order code still require project-specific confirmation.

PERFORMANCE NOTE

ROTAN CD: how to read the operating range

Maximum family flow: 250 m³/h; Maximum differential pressure: 16 bar; Maximum speed: 1,750 rpm; Maximum viscosity: 250,000 cSt. These figures describe the documented family or model reference; the usable duty point must be checked against speed, liquid properties, suction conditions and the selected drive.

MODEL IDENTIFICATION

ROTAN CD: model and configuration checklist

Use the complete nameplate designation, serial number, connection, materials, seal arrangement and drive details. DFIN confirms the configuration before quotation rather than treating a family name as a complete order code.

APPLICATION REVIEW

ROTAN CD: materials and suitable duties

Stainless-steel construction; application-specific bushes and seals. Typical duties to review include Compatible acids and alkalis, Resins, soaps and shampoo, Temperature-controlled process liquids. Provide concentration, operating temperature and cleaning chemicals. Confirm seal arrangement and material compatibility before evaluating the proposed speed.

SERVICE PLANNING

ROTAN CD: maintenance and spare-parts preparation

Use the pump serial number, complete designation and assembly drawing to identify the shaft seal or packing, rotor, idler, bushes, gaskets and relief-valve components. Isolate the equipment, follow the applicable maintenance procedure and confirm every replacement item against the installed configuration before ordering.

PRODUCT & ENGINEERING FAQ

Questions about DESMI ROTAN ROTAN CD

Use these answers to prepare a technically complete comparison and enquiry.

How should DESMI ROTAN ROTAN CD be selected?

Start with the real duty point: fluid, flow, differential pressure or head, temperature, viscosity, solids, suction condition and operating pattern. DFIN then reviews size, materials, sealing and drive.

Are the listed maximum values a guaranteed operating point?

No. They describe independent catalog boundaries for the family or model. The selected point must be checked against the applicable curve, size, speed, fluid and drive arrangement.

What information confirms the complete model code?

Provide the full nameplate designation and serial number plus materials, seal arrangement, ports, drive, motor supply and any special option. A family name alone is not an order code.

Can DFIN help identify service parts?

Yes. Send the equipment identity, drawing position, existing part code, photographs, material and failure description. DFIN can prepare a parts enquiry matched to the installed configuration.

What should be included in the quotation request?

Include quantity, fluid data, operating point, installation, connection standard, available utilities, hazardous-area requirements and delivery destination. For a replacement, include the nameplate and current drawing.

SHANGHAI DFIN PUMP CO., LTD.

Turn this reference into a clear quotation.

Send the full model and serial number, quantity, fluid, required flow and pressure, temperature, viscosity, installation details and delivery destination. For a replacement, attach the nameplate and existing drawing.

Prepare an enquiry for ROTAN CD

WeChat

Please contact DFIN by email or WhatsApp to request our WeChat contact details. A verified WeChat QR code is not available on this page yet.

Request WeChat details