MX5Published family, drawing or curve designation; confirm the complete order configuration.
Enquire with this reference →
CUCCHI · Product family
MX provides stainless-steel gear-pump options for transferring compatible process liquids. Size-specific curves and connection arrangements support selection across small and larger transfer duties.
EXPLORE THIS PRODUCT DOSSIER
ENGINEERING DATA
Published range for this family or model group. Maximum values are independent limits; the actual duty point depends on speed, fluid, size and configuration.
| Parameter | Published reference |
|---|---|
| Published viscosity range | 1–100,000 cP |
| Mechanical-seal design temperature | Up to 200 °C; actual materials govern |
| Packing design temperature | Up to 300 °C; actual materials govern |
IDENTIFY THE RIGHT BUILD
A family or hydraulic size is the starting reference. Include the complete nameplate designation, serial number, materials, seals, drive and connection details when ordering.
MX5Published family, drawing or curve designation; confirm the complete order configuration.
Enquire with this reference →MX10Published family, drawing or curve designation; confirm the complete order configuration.
Enquire with this reference →MX15Published family, drawing or curve designation; confirm the complete order configuration.
Enquire with this reference →MX25Published family, drawing or curve designation; confirm the complete order configuration.
Enquire with this reference →MX40Published family, drawing or curve designation; confirm the complete order configuration.
Enquire with this reference →MX50Published family, drawing or curve designation; confirm the complete order configuration.
Enquire with this reference →MX70Published family, drawing or curve designation; confirm the complete order configuration.
Enquire with this reference →MX100Published family, drawing or curve designation; confirm the complete order configuration.
Enquire with this reference →MX150Published family, drawing or curve designation; confirm the complete order configuration.
Enquire with this reference →AISI 316L standard construction; gear treatment and seal materials are application dependent.
Check for suspended solids and verify gear compatibility. Use viscosity-corrected curves and specify heating where required.
DFIN reviews the operating point together with the suction condition and drive. Supply the fluid properties at both start-up and normal operation so the proposed arrangement can be checked against the appropriate curve.
DFIN application links identify duties to discuss, subject to the specified fluid and complete pump configuration.
Identify gears, shafts, bushes and seals for gear pumps, or the liquid-end valves, piston seals and diaphragms for metering pumps, using the matching section drawing.
Provide the serial number, complete construction code and fluid details before a repair set is specified. Optional gear treatments, heating or magnetic drives change the required parts.
Use the selected model’s operating manual for isolation, draining, inspection and reassembly. Report leakage, unusual noise, loss of output or visible wear with photographs and the operating history. DFIN can use the equipment identity and drawing positions to prepare a parts enquiry.
Request matching service parts →DFIN KNOWLEDGE BASE
Shanghai Dfin Pump Co., Ltd. has reorganised the available product facts into practical notes for identification, selection, application review and maintenance planning. These notes support an initial comparison; the final duty point and order code still require project-specific confirmation.
PERFORMANCE NOTE
Published viscosity range: 1–100,000 cP; Mechanical-seal design temperature: Up to 200 °C; actual materials govern; Packing design temperature: Up to 300 °C; actual materials govern. These figures describe the documented family or model reference; the usable duty point must be checked against speed, liquid properties, suction conditions and the selected drive.
MODEL IDENTIFICATION
Identification references include MX5, MX10, MX15, MX25, MX40. Use the complete nameplate designation, serial number, connection, materials, seal arrangement and drive details when requesting a replacement or quotation.
APPLICATION REVIEW
AISI 316L standard construction; gear treatment and seal materials are application dependent. Typical duties to review include Resins, adhesives, polyols and isocyanates, Molasses, fats or chocolate with the specified food-contact construction. Check for suspended solids and verify gear compatibility. Use viscosity-corrected curves and specify heating where required.
SERVICE PLANNING
Identify gears, shafts, bushes and seals for gear pumps, or the liquid-end valves, piston seals and diaphragms for metering pumps, using the matching section drawing. Isolate the equipment, follow the applicable maintenance procedure and confirm every replacement item against the installed configuration before ordering.
PRODUCT & ENGINEERING FAQ
Use these answers to prepare a technically complete comparison and enquiry.
Start with the real duty point: fluid, flow, differential pressure or head, temperature, viscosity, solids, suction condition and operating pattern. DFIN then reviews size, materials, sealing and drive.
No. They describe independent catalog boundaries for the family or model. The selected point must be checked against the applicable curve, size, speed, fluid and drive arrangement.
Provide the full nameplate designation and serial number plus materials, seal arrangement, ports, drive, motor supply and any special option. A family name alone is not an order code.
Yes. Send the equipment identity, drawing position, existing part code, photographs, material and failure description. DFIN can prepare a parts enquiry matched to the installed configuration.
Include quantity, fluid data, operating point, installation, connection standard, available utilities, hazardous-area requirements and delivery destination. For a replacement, include the nameplate and current drawing.
SHANGHAI DFIN PUMP CO., LTD.
Send the full model and serial number, quantity, fluid, required flow and pressure, temperature, viscosity, installation details and delivery destination. For a replacement, attach the nameplate and existing drawing.
Prepare an enquiry for MX