CUCCHI Metering gear pump N for Detergent and cosmetic ingredient dosing

A gear-metering range for process liquids where consistent delivery and speed-based control are important. Stainless-steel bar-stock construction and selected sealing arrangements support chemical and formulation duties.

Family flow range0.5–60,000 L/h
Maximum published operating pressure15 bar
Published viscosity range1–100,000 cP
DFIN technical record reviewed 2026-09-15. Availability and complete order code are confirmed with your enquiry.

EXPLORE THIS PRODUCT DOSSIER

Product, engineering and service information in one place

ENGINEERING DATA

Technical specifications

Published range for this family or model group. Maximum values are independent limits; the actual duty point depends on speed, fluid, size and configuration.

ParameterPublished reference
Family flow range0.5–60,000 L/h
Maximum published operating pressure15 bar
Published viscosity range1–100,000 cP

IDENTIFY THE RIGHT BUILD

Models & configuration

A family or hydraulic size is the starting reference. Include the complete nameplate designation, serial number, materials, seals, drive and connection details when ordering.

Materials & performance

AISI 316L standard; specialist materials and magnetic-drive variants available for review.

Select from the individual curve, with viscosity and required dosing range. Specify the gear treatment and cleaning requirements.

DFIN reviews the operating point together with the suction condition and drive. Supply the fluid properties at both start-up and normal operation so the proposed arrangement can be checked against the appropriate curve.

Application industries

DFIN application links identify duties to discuss, subject to the specified fluid and complete pump configuration.

Typical duties to review

  • Detergent and cosmetic ingredient dosing
  • Liquid food ingredients subject to configured hygiene requirements

Compatible parts & service

Identify gears, shafts, bushes and seals for gear pumps, or the liquid-end valves, piston seals and diaphragms for metering pumps, using the matching section drawing.

Provide the serial number, complete construction code and fluid details before a repair set is specified. Optional gear treatments, heating or magnetic drives change the required parts.

Maintenance planning

Use the selected model’s operating manual for isolation, draining, inspection and reassembly. Report leakage, unusual noise, loss of output or visible wear with photographs and the operating history. DFIN can use the equipment identity and drawing positions to prepare a parts enquiry.

Request matching service parts →

DFIN KNOWLEDGE BASE

DFIN technical notes for N

Shanghai Dfin Pump Co., Ltd. has reorganised the available product facts into practical notes for identification, selection, application review and maintenance planning. These notes support an initial comparison; the final duty point and order code still require project-specific confirmation.

PERFORMANCE NOTE

N: how to read the operating range

Family flow range: 0.5–60,000 L/h; Maximum published operating pressure: 15 bar; Published viscosity range: 1–100,000 cP. These figures describe the documented family or model reference; the usable duty point must be checked against speed, liquid properties, suction conditions and the selected drive.

MODEL IDENTIFICATION

N: model and configuration checklist

Identification references include NAX 2.5, NAX 3.5, NAX 10, NBX 14, NBX 24. Use the complete nameplate designation, serial number, connection, materials, seal arrangement and drive details when requesting a replacement or quotation.

APPLICATION REVIEW

N: materials and suitable duties

AISI 316L standard; specialist materials and magnetic-drive variants available for review. Typical duties to review include Detergent and cosmetic ingredient dosing, Liquid food ingredients subject to configured hygiene requirements. Select from the individual curve, with viscosity and required dosing range. Specify the gear treatment and cleaning requirements.

SERVICE PLANNING

N: maintenance and spare-parts preparation

Identify gears, shafts, bushes and seals for gear pumps, or the liquid-end valves, piston seals and diaphragms for metering pumps, using the matching section drawing. Isolate the equipment, follow the applicable maintenance procedure and confirm every replacement item against the installed configuration before ordering.

PRODUCT & ENGINEERING FAQ

Questions about CUCCHI N

Use these answers to prepare a technically complete comparison and enquiry.

How should CUCCHI N be selected?

Start with the real duty point: fluid, flow, differential pressure or head, temperature, viscosity, solids, suction condition and operating pattern. DFIN then reviews size, materials, sealing and drive.

Are the listed maximum values a guaranteed operating point?

No. They describe independent catalog boundaries for the family or model. The selected point must be checked against the applicable curve, size, speed, fluid and drive arrangement.

What information confirms the complete model code?

Provide the full nameplate designation and serial number plus materials, seal arrangement, ports, drive, motor supply and any special option. A family name alone is not an order code.

Can DFIN help identify service parts?

Yes. Send the equipment identity, drawing position, existing part code, photographs, material and failure description. DFIN can prepare a parts enquiry matched to the installed configuration.

What should be included in the quotation request?

Include quantity, fluid data, operating point, installation, connection standard, available utilities, hazardous-area requirements and delivery destination. For a replacement, include the nameplate and current drawing.

SHANGHAI DFIN PUMP CO., LTD.

Turn this reference into a clear quotation.

Send the full model and serial number, quantity, fluid, required flow and pressure, temperature, viscosity, installation details and delivery destination. For a replacement, attach the nameplate and existing drawing.

Prepare an enquiry for N

WeChat

Please contact DFIN by email or WhatsApp to request our WeChat contact details. A verified WeChat QR code is not available on this page yet.

Request WeChat details