NAX 2.5Published family, drawing or curve designation; confirm the complete order configuration.
Enquire with this reference →
CUCCHI · Product family
A gear-metering range for process liquids where consistent delivery and speed-based control are important. Stainless-steel bar-stock construction and selected sealing arrangements support chemical and formulation duties.
EXPLORE THIS PRODUCT DOSSIER
ENGINEERING DATA
Published range for this family or model group. Maximum values are independent limits; the actual duty point depends on speed, fluid, size and configuration.
| Parameter | Published reference |
|---|---|
| Family flow range | 0.5–60,000 L/h |
| Maximum published operating pressure | 15 bar |
| Published viscosity range | 1–100,000 cP |
IDENTIFY THE RIGHT BUILD
A family or hydraulic size is the starting reference. Include the complete nameplate designation, serial number, materials, seals, drive and connection details when ordering.
NAX 2.5Published family, drawing or curve designation; confirm the complete order configuration.
Enquire with this reference →NAX 3.5Published family, drawing or curve designation; confirm the complete order configuration.
Enquire with this reference →NAX 10Published family, drawing or curve designation; confirm the complete order configuration.
Enquire with this reference →NBX 14Published family, drawing or curve designation; confirm the complete order configuration.
Enquire with this reference →NBX 24Published family, drawing or curve designation; confirm the complete order configuration.
Enquire with this reference →NCX 41Published family, drawing or curve designation; confirm the complete order configuration.
Enquire with this reference →NDX 68Published family, drawing or curve designation; confirm the complete order configuration.
Enquire with this reference →NDX 100Published family, drawing or curve designation; confirm the complete order configuration.
Enquire with this reference →NDX 136Published family, drawing or curve designation; confirm the complete order configuration.
Enquire with this reference →NEX 200Published family, drawing or curve designation; confirm the complete order configuration.
Enquire with this reference →NEX 300Published family, drawing or curve designation; confirm the complete order configuration.
Enquire with this reference →NEX 400Published family, drawing or curve designation; confirm the complete order configuration.
Enquire with this reference →NFX 750Published family, drawing or curve designation; confirm the complete order configuration.
Enquire with this reference →NFX M00Published family, drawing or curve designation; confirm the complete order configuration.
Enquire with this reference →NFX M60Published family, drawing or curve designation; confirm the complete order configuration.
Enquire with this reference →AISI 316L standard; specialist materials and magnetic-drive variants available for review.
Select from the individual curve, with viscosity and required dosing range. Specify the gear treatment and cleaning requirements.
DFIN reviews the operating point together with the suction condition and drive. Supply the fluid properties at both start-up and normal operation so the proposed arrangement can be checked against the appropriate curve.
DFIN application links identify duties to discuss, subject to the specified fluid and complete pump configuration.
Identify gears, shafts, bushes and seals for gear pumps, or the liquid-end valves, piston seals and diaphragms for metering pumps, using the matching section drawing.
Provide the serial number, complete construction code and fluid details before a repair set is specified. Optional gear treatments, heating or magnetic drives change the required parts.
Use the selected model’s operating manual for isolation, draining, inspection and reassembly. Report leakage, unusual noise, loss of output or visible wear with photographs and the operating history. DFIN can use the equipment identity and drawing positions to prepare a parts enquiry.
Request matching service parts →DFIN KNOWLEDGE BASE
Shanghai Dfin Pump Co., Ltd. has reorganised the available product facts into practical notes for identification, selection, application review and maintenance planning. These notes support an initial comparison; the final duty point and order code still require project-specific confirmation.
PERFORMANCE NOTE
Family flow range: 0.5–60,000 L/h; Maximum published operating pressure: 15 bar; Published viscosity range: 1–100,000 cP. These figures describe the documented family or model reference; the usable duty point must be checked against speed, liquid properties, suction conditions and the selected drive.
MODEL IDENTIFICATION
Identification references include NAX 2.5, NAX 3.5, NAX 10, NBX 14, NBX 24. Use the complete nameplate designation, serial number, connection, materials, seal arrangement and drive details when requesting a replacement or quotation.
APPLICATION REVIEW
AISI 316L standard; specialist materials and magnetic-drive variants available for review. Typical duties to review include Detergent and cosmetic ingredient dosing, Liquid food ingredients subject to configured hygiene requirements. Select from the individual curve, with viscosity and required dosing range. Specify the gear treatment and cleaning requirements.
SERVICE PLANNING
Identify gears, shafts, bushes and seals for gear pumps, or the liquid-end valves, piston seals and diaphragms for metering pumps, using the matching section drawing. Isolate the equipment, follow the applicable maintenance procedure and confirm every replacement item against the installed configuration before ordering.
PRODUCT & ENGINEERING FAQ
Use these answers to prepare a technically complete comparison and enquiry.
Start with the real duty point: fluid, flow, differential pressure or head, temperature, viscosity, solids, suction condition and operating pattern. DFIN then reviews size, materials, sealing and drive.
No. They describe independent catalog boundaries for the family or model. The selected point must be checked against the applicable curve, size, speed, fluid and drive arrangement.
Provide the full nameplate designation and serial number plus materials, seal arrangement, ports, drive, motor supply and any special option. A family name alone is not an order code.
Yes. Send the equipment identity, drawing position, existing part code, photographs, material and failure description. DFIN can prepare a parts enquiry matched to the installed configuration.
Include quantity, fluid data, operating point, installation, connection standard, available utilities, hazardous-area requirements and delivery destination. For a replacement, include the nameplate and current drawing.
SHANGHAI DFIN PUMP CO., LTD.
Send the full model and serial number, quantity, fluid, required flow and pressure, temperature, viscosity, installation details and delivery destination. For a replacement, attach the nameplate and existing drawing.
Prepare an enquiry for NOnline support

Hi! How can we help?
We normally reply during China business hours.