Skip to content
dfin88@dfinsewagepump.com+86 21 31263176Industrial pump solutions since 2012
DESMI ROTAN HD81 — DFIN catalog reference
DFIN catalog image. Final materials, drive and supplied configuration follow the confirmed quotation.

DESMI ROTAN · Model size reference

DESMI ROTAN Internal gear pump — size reference HD81 for Replacement identification for an installed HD81

HD81 identifies a size within the heavy-duty ROTAN cast-iron family. This page supports identification and replacement enquiries, including the full designation supplied to DFIN: HD81EFCHD-1M22B.

FamilyROTAN HD
Nominal size reference81 / DN 80 / 3 in (manual code chart)
Individual flow, speed and pressureConfirm from the selected configuration and duty curve
DFIN technical record reviewed 2026-09-15. Availability and complete order code are confirmed with your enquiry.

EXPLORE THIS PRODUCT DOSSIER

Product, engineering and service information in one place

ENGINEERING DATA

Technical specifications

Published range for this family or model group. Maximum values are independent limits; the actual duty point depends on speed, fluid, size and configuration.

ParameterPublished reference
FamilyROTAN HD
Nominal size reference81 / DN 80 / 3 in (manual code chart)
Individual flow, speed and pressureConfirm from the selected configuration and duty curve
Enquiry designationHD81EFCHD-1M22B — full build unverified

IDENTIFY THE RIGHT BUILD

Models & configuration

A family or hydraulic size is the starting reference. Include the complete nameplate designation, serial number, materials, seals, drive and connection details when ordering.

HD81EFCHD-1M22B

Customer-supplied enquiry reference. Exact assembled configuration requires manufacturer or nameplate confirmation.

Enquire with this reference →

Reading the ROTAN designation

This is a positional reading of the published code chart, not verification that the complete customer-supplied designation is an available or correctly configured assembly.

HD / 81
Heavy-duty cast iron / nominal DN 80 size
E / F
Straight-through connection arrangement / flange code
CHD
Special chocolate-duty arrangement described by the manual
1 / M / 2 / 2 / B
Cast iron / external bearing lubrication / bronze idler bush / bronze main bush / packing

Materials & performance

Cast-iron construction; bearing and seal materials depend on the designation.

Send a clear nameplate photo and serial number. Include start-up and running viscosity, temperature, required flow and differential pressure. A family maximum must not be used as the HD81 duty point.

DFIN reviews the operating point together with the suction condition and drive. Supply the fluid properties at both start-up and normal operation so the proposed arrangement can be checked against the appropriate curve.

Application industries

DFIN application links identify duties to discuss, subject to the specified fluid and complete pump configuration.

Typical duties to review

  • Replacement identification for an installed HD81
  • Heated viscous-liquid transfer after configuration review

ROTAN documentation does not establish FDA / 3-A approval for these pumps. A food-related duty needs a separate review of hygiene, cleaning and the required documentation.

Compatible parts & service

Use the pump serial number, complete designation and assembly drawing to identify the shaft seal or packing, rotor, idler, bushes, gaskets and relief-valve components.

Send the required component positions and the existing material codes with your enquiry. Kit numbers are confirmed against the pump build; a WILDEN Air Kit or Wet Kit does not apply to this gear-pump design.

Maintenance planning

Use the selected model’s operating manual for isolation, draining, inspection and reassembly. Report leakage, unusual noise, loss of output or visible wear with photographs and the operating history. DFIN can use the equipment identity and drawing positions to prepare a parts enquiry.

Request matching service parts →

DFIN KNOWLEDGE BASE

DFIN technical notes for ROTAN HD81

Shanghai Dfin Pump Co., Ltd. has reorganised the available product facts into practical notes for identification, selection, application review and maintenance planning. These notes support an initial comparison; the final duty point and order code still require project-specific confirmation.

PERFORMANCE NOTE

ROTAN HD81: how to read the operating range

Family: ROTAN HD; Nominal size reference: 81 / DN 80 / 3 in (manual code chart); Individual flow, speed and pressure: Confirm from the selected configuration and duty curve; Enquiry designation: HD81EFCHD-1M22B — full build unverified. These figures describe the documented family or model reference; the usable duty point must be checked against speed, liquid properties, suction conditions and the selected drive.

MODEL IDENTIFICATION

ROTAN HD81: model and configuration checklist

Identification references include HD81, HD81EFCHD-1M22B. Use the complete nameplate designation, serial number, connection, materials, seal arrangement and drive details when requesting a replacement or quotation.

APPLICATION REVIEW

ROTAN HD81: materials and suitable duties

Cast-iron construction; bearing and seal materials depend on the designation. Typical duties to review include Replacement identification for an installed HD81, Heated viscous-liquid transfer after configuration review. Send a clear nameplate photo and serial number. Include start-up and running viscosity, temperature, required flow and differential pressure. A family maximum must not be used as the HD81 duty point.

SERVICE PLANNING

ROTAN HD81: maintenance and spare-parts preparation

Use the pump serial number, complete designation and assembly drawing to identify the shaft seal or packing, rotor, idler, bushes, gaskets and relief-valve components. Isolate the equipment, follow the applicable maintenance procedure and confirm every replacement item against the installed configuration before ordering.

PRODUCT & ENGINEERING FAQ

Questions about DESMI ROTAN ROTAN HD81

Use these answers to prepare a technically complete comparison and enquiry.

How should DESMI ROTAN ROTAN HD81 be selected?

Start with the real duty point: fluid, flow, differential pressure or head, temperature, viscosity, solids, suction condition and operating pattern. DFIN then reviews size, materials, sealing and drive.

Are the listed maximum values a guaranteed operating point?

No. They describe independent catalog boundaries for the family or model. The selected point must be checked against the applicable curve, size, speed, fluid and drive arrangement.

What information confirms the complete model code?

Provide the full nameplate designation and serial number plus materials, seal arrangement, ports, drive, motor supply and any special option. A family name alone is not an order code.

Can DFIN help identify service parts?

Yes. Send the equipment identity, drawing position, existing part code, photographs, material and failure description. DFIN can prepare a parts enquiry matched to the installed configuration.

What should be included in the quotation request?

Include quantity, fluid data, operating point, installation, connection standard, available utilities, hazardous-area requirements and delivery destination. For a replacement, include the nameplate and current drawing.

SHANGHAI DFIN PUMP CO., LTD.

Turn this reference into a clear quotation.

Send the full model and serial number, quantity, fluid, required flow and pressure, temperature, viscosity, installation details and delivery destination. For a replacement, attach the nameplate and existing drawing.

Prepare an enquiry for ROTAN HD81

WeChat

Please contact DFIN by email or WhatsApp to request our WeChat contact details. A verified WeChat QR code is not available on this page yet.

Request WeChat details