CD26DFIN configuration/reference page based on DESMI's published designation system. It is not presented as a manufacturer-confirmed stocked SKU; the complete order code requires DESMI verification.
Enquire with this reference →
DESMI ROTAN · Configuration reference
CD26 Inline Flanged Packing is organised by DFIN as a CD Series selection reference for DN25 / 1". DFIN configuration/reference page based on DESMI's published designation system. It is not presented as a manufacturer-confirmed stocked SKU; the complete order code requires DESMI verification.
EXPLORE THIS PRODUCT DOSSIER
ENGINEERING DATA
Family maximum values are independent catalogue limits. They are not guaranteed simultaneous operating points for every size or configuration.
| Parameter | Published reference |
|---|---|
| Family | ROTAN CD |
| Nominal size reference | 26 / DN25 / 1" |
| Configuration reference | Inline Flanged Packing (E / F) |
| Seal arrangement | Packing / stuffing box |
| Maximum family flow | 250 m³/h |
| Maximum differential pressure | 16 bar |
| Maximum speed | 1,750 rpm |
| Maximum viscosity | 250,000 cSt |
| Maximum liquid temperature | 250 °C |
IDENTIFY THE RIGHT BUILD
A family or hydraulic size is the starting reference. Include the complete nameplate designation, serial number, materials, seals, drive and connection details when ordering.
CD26DFIN configuration/reference page based on DESMI's published designation system. It is not presented as a manufacturer-confirmed stocked SKU; the complete order code requires DESMI verification.
Enquire with this reference →Stainless-steel construction; bush, seal and elastomer materials require chemical-compatibility review.
Provide liquid, concentration, start-up and operating temperature, viscosity, required flow, differential pressure, suction condition, connection standard, installation orientation, hazardous-area requirement, motor/drive supply and delivery destination. Confirm the complete order code before quotation.
DFIN reviews the operating point together with the suction condition and drive. Supply the fluid properties at both start-up and normal operation so the proposed arrangement can be checked against the appropriate curve.
DFIN application links identify duties to discuss, subject to the specified fluid and complete pump configuration.
Use the complete nameplate designation and serial number when identifying replacement pumps or service parts.
DFIN verifies the selected size, materials, bearing arrangement, shaft seal, connection standard and drive against the actual duty before quotation.
Use the selected model’s operating manual for isolation, draining, inspection and reassembly. Report leakage, unusual noise, loss of output or visible wear with photographs and the operating history. DFIN can use the equipment identity and drawing positions to prepare a parts enquiry.
Request matching service parts →DFIN KNOWLEDGE BASE
Shanghai Dfin Pump Co., Ltd. has reorganised the available product facts into practical notes for identification, selection, application review and maintenance planning. These notes support an initial comparison; the final duty point and order code still require project-specific confirmation.
PERFORMANCE NOTE
Family: ROTAN CD; Nominal size reference: 26 / DN25 / 1"; Configuration reference: Inline Flanged Packing (E / F); Seal arrangement: Packing / stuffing box. These figures describe the documented family or model reference; the usable duty point must be checked against speed, liquid properties, suction conditions and the selected drive.
MODEL IDENTIFICATION
Identification references include CD26. Use the complete nameplate designation, serial number, connection, materials, seal arrangement and drive details when requesting a replacement or quotation.
APPLICATION REVIEW
Stainless-steel construction; bush, seal and elastomer materials require chemical-compatibility review. Typical duties to review include Compatible acids, alkalis and specialty-chemical transfer, Resins, soaps, shampoo, polymer solutions and other compatible chemicals. Provide liquid, concentration, start-up and operating temperature, viscosity, required flow, differential pressure, suction condition, connection standard, installation orientation, hazardous-area requirement, motor/drive supply and delivery destination. Confirm the complete order code before quotation.
SERVICE PLANNING
Use the complete nameplate designation and serial number when identifying replacement pumps or service parts. Isolate the equipment, follow the applicable maintenance procedure and confirm every replacement item against the installed configuration before ordering.
PRODUCT & ENGINEERING FAQ
Use these answers to prepare a technically complete comparison and enquiry.
Start with the real duty point: fluid, flow, differential pressure or head, temperature, viscosity, solids, suction condition and operating pattern. DFIN then reviews size, materials, sealing and drive.
No. They describe independent catalog boundaries for the family or model. The selected point must be checked against the applicable curve, size, speed, fluid and drive arrangement.
Provide the full nameplate designation and serial number plus materials, seal arrangement, ports, drive, motor supply and any special option. A family name alone is not an order code.
Yes. Send the equipment identity, drawing position, existing part code, photographs, material and failure description. DFIN can prepare a parts enquiry matched to the installed configuration.
Include quantity, fluid data, operating point, installation, connection standard, available utilities, hazardous-area requirements and delivery destination. For a replacement, include the nameplate and current drawing.
SHANGHAI DFIN PUMP CO., LTD.
Send the full model and serial number, quantity, fluid, required flow and pressure, temperature, viscosity, installation details and delivery destination. For a replacement, attach the nameplate and existing drawing.
Prepare an enquiry for CD26 Inline Flanged Packing