SP10Published hydraulic model; the full material, motor and connection code is configured separately.
Enquire with this reference →FTI / Finish Thompson · Model family
A sealless magnetic-drive centrifugal model for compatible chemical service. The self-priming arrangement is relevant when suction conditions require this function.
EXPLORE THIS PRODUCT DOSSIER
ENGINEERING DATA
Published 2,900 rpm hydraulic range. Power values are based on specific gravity 1.0; impeller diameter and liquid properties determine the selected operating point.
| Parameter | Published reference |
|---|---|
| Suction × discharge | 1 × 1 in |
| Published flow range at 2,900 rpm | 0.114–12.2 m³/h |
| Maximum head at 2,900 rpm | 13.7 m |
| Maximum working pressure | 5.5 bar |
| Published power range at 2,900 rpm | 0.10–0.63 kW |
IDENTIFY THE RIGHT BUILD
A family or hydraulic size is the starting reference. Include the complete nameplate designation, serial number, materials, seals, drive and connection details when ordering.
SP10Published hydraulic model; the full material, motor and connection code is configured separately.
Enquire with this reference →Select casing, impeller, bearing and O-ring materials from the model specification.
Provide duty flow and head, suction level and liquid properties. Check the curve at the intended speed and verify any minimum-flow or priming requirement.
DFIN reviews the operating point together with the suction condition and drive. Supply the fluid properties at both start-up and normal operation so the proposed arrangement can be checked against the appropriate curve.
DFIN application links identify duties to discuss, subject to the specified fluid and complete pump configuration.
Service items include the impeller assembly, thrust ring, bushing, shaft, O-rings, barrier and drive magnet, according to the model drawing.
Drawing callout positions are not orderable part codes. Send the serial number and actual material arrangement to identify replacement parts.
Use the selected model’s operating manual for isolation, draining, inspection and reassembly. Report leakage, unusual noise, loss of output or visible wear with photographs and the operating history. DFIN can use the equipment identity and drawing positions to prepare a parts enquiry.
Request matching service parts →DFIN KNOWLEDGE BASE
Shanghai Dfin Pump Co., Ltd. has reorganised the available product facts into practical notes for identification, selection, application review and maintenance planning. These notes support an initial comparison; the final duty point and order code still require project-specific confirmation.
PERFORMANCE NOTE
Suction × discharge: 1 × 1 in; Published flow range at 2,900 rpm: 0.114–12.2 m³/h; Maximum head at 2,900 rpm: 13.7 m; Maximum working pressure: 5.5 bar. These figures describe the documented family or model reference; the usable duty point must be checked against speed, liquid properties, suction conditions and the selected drive.
MODEL IDENTIFICATION
Identification references include SP10. Use the complete nameplate designation, serial number, connection, materials, seal arrangement and drive details when requesting a replacement or quotation.
APPLICATION REVIEW
Select casing, impeller, bearing and O-ring materials from the model specification. Typical duties to review include Compatible chemical circulation and transfer, Treatment-chemical and process utility duties. Provide duty flow and head, suction level and liquid properties. Check the curve at the intended speed and verify any minimum-flow or priming requirement.
SERVICE PLANNING
Service items include the impeller assembly, thrust ring, bushing, shaft, O-rings, barrier and drive magnet, according to the model drawing. Isolate the equipment, follow the applicable maintenance procedure and confirm every replacement item against the installed configuration before ordering.
PRODUCT & ENGINEERING FAQ
Use these answers to prepare a technically complete comparison and enquiry.
Start with the real duty point: fluid, flow, differential pressure or head, temperature, viscosity, solids, suction condition and operating pattern. DFIN then reviews size, materials, sealing and drive.
No. They describe independent catalog boundaries for the family or model. The selected point must be checked against the applicable curve, size, speed, fluid and drive arrangement.
Provide the full nameplate designation and serial number plus materials, seal arrangement, ports, drive, motor supply and any special option. A family name alone is not an order code.
Yes. Send the equipment identity, drawing position, existing part code, photographs, material and failure description. DFIN can prepare a parts enquiry matched to the installed configuration.
Include quantity, fluid data, operating point, installation, connection standard, available utilities, hazardous-area requirements and delivery destination. For a replacement, include the nameplate and current drawing.
SHANGHAI DFIN PUMP CO., LTD.
Send the full model and serial number, quantity, fluid, required flow and pressure, temperature, viscosity, installation details and delivery destination. For a replacement, attach the nameplate and existing drawing.
Prepare an enquiry for SP10Online support

Hi! How can we help?