Skip to content
dfin88@dfinsewagepump.com+86 21 31263176Industrial pump solutions since 2012
FTI / Finish ThompsonEFPPolypropylene drum pump
Product photography is not yet available here. Use the DFIN technical notes and product data below for an initial review.

FTI / Finish Thompson · Model family

FTI / Finish Thompson Polypropylene drum pump EFP for Compatible cleaners, coolants and light chemical solutions

A lightweight drum-transfer pump for compatible liquids. The narrow tube and available immersion lengths support portable container-emptying duties.

Maximum flow — electric-drive envelope64 L/min
Maximum head — electric-drive envelope6.1 m
Maximum published viscosity300 cP
DFIN technical record reviewed 2026-09-15. Availability and complete order code are confirmed with your enquiry.

EXPLORE THIS PRODUCT DOSSIER

Product, engineering and service information in one place

ENGINEERING DATA

Technical specifications

Published range for this family or model group. Maximum values are independent limits; the actual duty point depends on speed, fluid, size and configuration.

ParameterPublished reference
Maximum flow — electric-drive envelope64 L/min
Maximum head — electric-drive envelope6.1 m
Maximum published viscosity300 cP
Published temperature range−18 to 66 °C

IDENTIFY THE RIGHT BUILD

Models & configuration

A family or hydraulic size is the starting reference. Include the complete nameplate designation, serial number, materials, seals, drive and connection details when ordering.

Materials & performance

Polypropylene tube and impeller; 316 stainless-steel shaft; FKM O-ring.

Check chemical concentration and container opening. The values shown are for the electric-drive arrangement; air and 12 V variants have different envelopes.

DFIN reviews the operating point together with the suction condition and drive. Supply the fluid properties at both start-up and normal operation so the proposed arrangement can be checked against the appropriate curve.

Application industries

DFIN application links identify duties to discuss, subject to the specified fluid and complete pump configuration.

Typical duties to review

  • Compatible cleaners, coolants and light chemical solutions

Compatible parts & service

Use the model, tube length, serial number and motor identification to specify the impeller or rotor, shaft, seals and other service components. HVDP assemblies also require the correct stator.

Confirm whether the requested supply includes tube, motor, hose, nozzle and connections. These components are not assumed to be included with a bare pump tube.

Maintenance planning

Use the selected model’s operating manual for isolation, draining, inspection and reassembly. Report leakage, unusual noise, loss of output or visible wear with photographs and the operating history. DFIN can use the equipment identity and drawing positions to prepare a parts enquiry.

Request matching service parts →

DFIN KNOWLEDGE BASE

DFIN technical notes for EFP

Shanghai Dfin Pump Co., Ltd. has reorganised the available product facts into practical notes for identification, selection, application review and maintenance planning. These notes support an initial comparison; the final duty point and order code still require project-specific confirmation.

PERFORMANCE NOTE

EFP: how to read the operating range

Maximum flow — electric-drive envelope: 64 L/min; Maximum head — electric-drive envelope: 6.1 m; Maximum published viscosity: 300 cP; Published temperature range: −18 to 66 °C. These figures describe the documented family or model reference; the usable duty point must be checked against speed, liquid properties, suction conditions and the selected drive.

MODEL IDENTIFICATION

EFP: model and configuration checklist

Identification references include EFP. Use the complete nameplate designation, serial number, connection, materials, seal arrangement and drive details when requesting a replacement or quotation.

APPLICATION REVIEW

EFP: materials and suitable duties

Polypropylene tube and impeller; 316 stainless-steel shaft; FKM O-ring. Typical duties to review include Compatible cleaners, coolants and light chemical solutions. Check chemical concentration and container opening. The values shown are for the electric-drive arrangement; air and 12 V variants have different envelopes.

SERVICE PLANNING

EFP: maintenance and spare-parts preparation

Use the model, tube length, serial number and motor identification to specify the impeller or rotor, shaft, seals and other service components. HVDP assemblies also require the correct stator. Isolate the equipment, follow the applicable maintenance procedure and confirm every replacement item against the installed configuration before ordering.

PRODUCT & ENGINEERING FAQ

Questions about FTI / Finish Thompson EFP

Use these answers to prepare a technically complete comparison and enquiry.

How should FTI / Finish Thompson EFP be selected?

Start with the real duty point: fluid, flow, differential pressure or head, temperature, viscosity, solids, suction condition and operating pattern. DFIN then reviews size, materials, sealing and drive.

Are the listed maximum values a guaranteed operating point?

No. They describe independent catalog boundaries for the family or model. The selected point must be checked against the applicable curve, size, speed, fluid and drive arrangement.

What information confirms the complete model code?

Provide the full nameplate designation and serial number plus materials, seal arrangement, ports, drive, motor supply and any special option. A family name alone is not an order code.

Can DFIN help identify service parts?

Yes. Send the equipment identity, drawing position, existing part code, photographs, material and failure description. DFIN can prepare a parts enquiry matched to the installed configuration.

What should be included in the quotation request?

Include quantity, fluid data, operating point, installation, connection standard, available utilities, hazardous-area requirements and delivery destination. For a replacement, include the nameplate and current drawing.

SHANGHAI DFIN PUMP CO., LTD.

Turn this reference into a clear quotation.

Send the full model and serial number, quantity, fluid, required flow and pressure, temperature, viscosity, installation details and delivery destination. For a replacement, attach the nameplate and existing drawing.

Prepare an enquiry for EFP

WeChat

Please contact DFIN by email or WhatsApp to request our WeChat contact details. A verified WeChat QR code is not available on this page yet.

Request WeChat details